Wire Rope Breaking Strength Chart

Minimum breaking force of 6×19 fibre-core wire rope in inch and mm sizes.

Minimum breaking force (MBF) is the load a new rope must reach before it fails. It is not a load you may lift. To get a working figure, you divide MBF by a design factor, then allow for the end fittings, the angle of the legs and the rope's condition. The tables give MBF for common 6×19 fibre-core rope in inch and metric sizes. A half-inch rope of this type breaks at about 21,400 lbf (95 kN), and its share of a lift is far lower. These figures are for new rope. They are not sling working loads. Never use this table to lift people.

Inch sizes: 6×19 fibre core, improved plow steel (IPS)

Minimum breaking force of new rope. This is not a sling working load. Stronger grades and steel cores carry more: a ½ in 6×19 extra improved plow steel rope with a steel core is listed at about 26,600 lbf, so read the data for your exact rope.

DiameterMinimum breaking force (lbf)Minimum breaking force (kN)
¼ in5,48024.4
⅜ in12,20054.3
½ in21,40095.2
⅝ in33,400148.6
¾ in47,600211.7
⅞ in64,400286.5
1 in83,600371.9

7 rows

Metric sizes: 6×19 fibre core, 1770 and 1960 N/mm² grades

Minimum breaking force of new rope, not a sling working load. EN 12385-4 gives Fmin = K × d² × R ÷ 1000, with d in mm and R the wire grade in N/mm²; for 6×19 with a fibre core, K is 0.330. Grade 1770 is close to US IPS.

Diameter (mm)Minimum breaking force, grade 1770 (kN)Minimum breaking force, grade 1960 (kN)
621.023.3
837.441.4
1058.464.7
1284.193.1
16150166
20234259
24336373
28458507
32598662
36757838
409351,035

11 rows

From breaking force to a working load

Lifting must follow the rated capacity on the sling tag or the equipment, and the rules that apply where you work.

  • Start with the rope certificate, not a table.
  • Divide by the design factor. For wire rope slings, 5 is the usual minimum under ASME B30.9. Other equipment has its own figure, set by the standard for that equipment. See What Is Factor of Safety?
  • Allow for the end fitting. An eye, a splice or clips can be weaker than the rope. A sling tag already includes this, and a bare rope figure does not.
  • Allow for the angle, and include the rigging in the weight. The wire rope weight calculator helps with long falls.

Sling angle: the part most often missed

As a sling flattens, each leg pulls harder for the same load. The load one leg can support vertically is its rating × sin(angle from horizontal). Take two legs, each tagged 2 t for a straight pull. At 60° they lift 3.46 t, at 45° they lift 2.83 t, and at 30° they lift only 2 t: what one leg carries straight. This is geometry, and the tag for your sling comes first.

  • 90° (vertical): factor 1.000
  • 60°: factor 0.866
  • 45°: factor 0.707
  • 30°: factor 0.500

6×19 or 6×37?

The first number counts strands and the second the wires in each. Fewer, thicker wires resist abrasion. More, finer wires bend better around sheaves and resist fatigue. So 6×19 suits slings and general rigging, and 6×37 suits drums and sheaves. For the same diameter, strength depends on grade and core as well, so check the maker's table rather than the name. The word strength here means force, unlike material tensile strength, which is a stress.

When to retire a rope

For wire rope slings, ASME B30.9 removal criteria include 10 randomly broken wires in one rope lay, or 5 in one strand of one lay. Also remove a rope for kinks, crushing, birdcaging, heat damage, severe corrosion or a missing tag. Crane ropes follow their own rules, such as ISO 4309. Ropes lose strength in service, so MBF applies only to new rope.

By O.E. — Partner, chairman of the board and CEO of a metal products manufacturer for 21 years; the company exports to 45 countries.

Drafted with AI assistance; calculations checked against primary sources and tested with the site's own code. About FlowUtil

Last reviewed

About the Wire Rope Breaking Strength Chart

Sources

Classification: Minimum breaking force of new rope: formula and catalogue values (verification required)

Sources

  • EN 12385-4 — Steel wire ropes — Stranded ropes for general lifting applications (minimum breaking force)

    CEN (European Committee for Standardisation)

  • Wire Ropes — Strengths (6×19 FC IPS, inch sizes)

    Engineering ToolBox

  • ASME B30.9 — Slings (design factor and removal criteria)

    ASME

Minimum breaking force (MBF) depends on rope construction, the wire grade and the core. Metric values follow the EN 12385-4 formula with K = 0.330 for 6×19 fibre-core rope; inch values are published IPS figures. MBF is a property of new rope and is not a sling working load: use the rope certificate and the sling tag for any lift.

How it was compiled

MBF is the minimum load at which a new rope must fail in a proof test, set by the standard as a function of construction and wire grade. Real ropes fail above this minimum. Weight per metre follows from the steel density and the rope’s metallic cross-section.

How current it is

Classification: Grade- and manufacturer-dependent (verification required)

MBF values are stable as standard minimums, but the applicable value for a specific rope depends on construction, grade and manufacturer. Always use the rope’s test certificate for lifting design — never the tabulated indicative value.

Limitations

  • Tabulated MBF is a minimum for new rope; use the value on the rope certificate.
  • Working load is a fraction of MBF, set by the design factor for the equipment, the end fittings and the sling angle. Never use MBF as a working load.
  • Rope performance degrades with wear, fatigue and corrosion; in-service strength is lower than the new-rope MBF.
  • Different constructions have different flexibility and fatigue characteristics even at the same MBF.

Using it

  • For any lifting or load-bearing application, use the rope manufacturer’s test certificate, not the tabulated indicative MBF.
  • Apply the correct design factor (per the governing lifting standard) to MBF to obtain the allowable working load.
  • Inspect and retire ropes per the applicable standard; in-service strength falls below the new-rope MBF.

Units and notation

Diameter in inches or millimetres; MBF in pounds-force or kilonewtons.

Frequently Asked Questions

How strong is ½ inch wire rope?

A 6×19 fibre-core IPS rope breaks at about 21,400 lbf (95 kN). That is not a lifting rating.

What is the difference between breaking strength and working load?

Breaking strength is failure. Working load is the much lower rated load after a design factor and fittings.

What does 6×19 mean?

Six strands of about 19 wires each.

What does IPS mean?

Improved plow steel, a grade of wire. EIPS is a stronger grade.

What is the design factor for wire rope slings?

Usually 5, under ASME B30.9.

Does a sling angle reduce capacity?

Yes. At 30° from horizontal, a leg gives half its vertical rating.