Drywall Thickness Chart — Types, Fire Ratings & Applications

Thickness, weight and type of gypsum board for walls, ceilings, garages and wet rooms.

Most interior walls in the US are finished in ½ in drywall, and most ceilings on wider framing and fire-separation work use ⅝ in. Thinner sheets are for curves and overlays. In the UK and Europe the same material is called plasterboard and comes in 9.5, 12.5 and 15 mm. Thickness decides how flat a wall stays and how much it weighs, and the type decides how it behaves in a fire or in a damp room. The tables below give the sizes, the weights from manufacturers' data, and the points where a building code, not a preference, sets the choice.

US Gypsum Board Thicknesses and Weights

Weights vary by product and maker; lightweight ½ in boards are lighter still. Sheets are 4 ft wide and 8, 10 or 12 ft long (1219 × 2438 mm for a 4 × 8).

ThicknessMetricWeight (lb/ft²)Weight (kg/m²)4 × 8 ft SheetTypical Use
¼ in6.4 mm1.135.536 lbCurves, overlaying old walls
⅜ in9.5 mm1.256.140 lbRepairs, overlaying plaster
½ in12.7 mm1.607.851 lbStandard walls and ceilings
⅝ in Type X15.9 mm2.210.770 lbFire-rated work, ceilings at 24 in

4 rows

UK and European Plasterboard

Standard wallboard is EN 520 Type A. Other letters mark other properties, including F for fire and H for reduced water absorption; check the maker's sheet.

ThicknessWeight (kg/m²)2400 × 1200 mm Sheet
9.5 mm6.117.6 kg
12.5 mm8.123.3 kg
15 mm10.129.1 kg

3 rows

Choosing the Board Type

BoardKey FeatureStandardWhere It Goes
RegularGypsum core, paper facesASTM C1396Dry walls and ceilings
Type XGlass fibre in the coreASTM C1396Rated assemblies, garage ceilings
Type CBetter fire performance than Type XASTM C1396High-rating assemblies
Water-resistant backingMoisture-resistant core and facingASTM C1396Damp areas, not wet ones
Glass-mat gypsumNo paper to feed mouldASTM C1177High humidity, exterior sheathing
Cement backer boardCement coreANSI A118.9, ASTM C1325Tile in wet areas, with a membrane

6 rows

Fire: the rating belongs to the assembly

A fire rating belongs to a tested assembly, not to a board. To get the rating, build the listed assembly exactly: the same board, framing, fasteners, spacing and insulation. ASTM C1396 describes ⅝ in Type X as giving 1 hour and ½ in Type X as giving ¾ hour when applied to load-bearing 2 × 4 framing. Type X and Type C cannot be swapped unless the listing allows it.

Attached garages in the US

The International Residential Code asks for at least ½ in gypsum board on the garage side between a garage and a house or attic, and at least ⅝ in Type X on a garage ceiling below habitable rooms.

  • From the house and attic: ½ in gypsum board.
  • From habitable rooms above: ⅝ in Type X.
  • Structure supporting those floors or ceilings: ½ in gypsum board.
  • Those are minimums from one model code. States and cities change them, and they do not apply outside the US.

Ceilings: where sag decides

A ceiling sheet hangs from its fasteners, so it must be stiffer than a wall. Run sheets across the joists, and use ⅝ in or ½ in sag-resistant board at 24 in spacing. Where water-based texture will be sprayed on a ceiling, the IRC raises the minimum to ½ in at 16 in spacing and ⅝ in at 24 in, unless ½ in sag-resistant board is used.

Bathrooms and showers

Water-resistant gypsum board suits damp rooms, but the Tile Council of North America's guidance rules out gypsum board of any kind as a direct tile backing in wet areas. In a shower or tub surround use cement backer board or another rated backer, and add a waterproofing membrane. Cement board resists water damage but is not itself waterproof.

A 12 × 16 ft room

The walls of a room 12 by 16 ft and 8 ft high total 448 ft². With 4 × 8 ft sheets that is 448 ÷ 32 = 14 sheets, or 16 with 10% waste. In ½ in board they weigh about 800 lb, so plan how they get upstairs.

By O.E. — Partner, chairman of the board and CEO of a metal products manufacturer for 21 years; the company exports to 45 countries.

Drafted with AI assistance; calculations checked against primary sources and tested with the site's own code. About FlowUtil

Last reviewed

About the Drywall Thickness Chart

Sources

Classification: Published standards, model code and manufacturers' data

Sources

  • ASTM C1396 — Standard Specification for Gypsum Board

    ASTM International

    standard previews; full text not opened

  • International Residential Code, Table R302.6 and Section R702.3

    International Code Council

    read through published building-department handouts

  • Sheetrock Firecode X specification; gypsum board data sheet; wallboard data sheet

    USG; CertainTeed; Knauf

    weights

  • Tile and Stone Backer Board Selection Guide, quoting Tile Council of North America guidance

    Laticrete

    ANSI A118.9, ANSI A118.10 and wet-area use

Weights are manufacturers' figures and vary by product. Fire ratings belong to tested assemblies, not to boards. Code requirements are minimums from one model code and change with the edition and local amendments.

How it was compiled

US gypsum board is made in standard thicknesses (½ in and ⅝ in are the most common); European plasterboard in 9.5, 12.5 and 15 mm. Type X and Type C contain fibres and additives that delay fire penetration, enabling rated assemblies. The rating is a property of the full tested assembly (board, framing, fasteners, insulation).

How current it is

Classification: Stable (mature standard); codes change by edition

Gypsum board thicknesses and types have been stable for decades. Confirm the code edition your jurisdiction has adopted.

Limitations

  • Fire ratings are assembly ratings, not board properties; the framing, fasteners and insulation must match the tested assembly.
  • Type X and Type C are not interchangeable for all rated assemblies; use the type the assembly was tested with.
  • Framing spacing limits are not listed here: they depend on the board, its direction and the finish, so take them from GA-216 or your code.

Using it

  • Select the type and thickness to match a tested rated assembly for fire-rated construction.
  • Use the assembly's framing, fastener and joint details; the board alone does not deliver the rating.
  • For non-rated partitions, choose thickness by the required stiffness and acoustic performance.

Units and notation

Thickness in inches and millimetres; weight in lb/ft² and kg/m²; fire rating in hours.

Frequently Asked Questions

What thickness of drywall is standard for walls?

½ in (12.7 mm) in the US, 12.5 mm in the UK.

Should I use ½ in or ⅝ in drywall?

½ in for most walls; ⅝ in for ceilings on 24 in framing, sound control and rated assemblies.

How much does a sheet of drywall weigh?

About 51 lb for ½ in and 70 lb for ⅝ in Type X, at 4 × 8 ft.

Do I need Type X in a garage?

On the ceiling under a habitable room, yes, under the IRC. Elsewhere ½ in board is the model code's minimum. Check your local code.

What is Type X drywall?

Board with glass fibres in the core that hold it together longer in a fire.

Can I use regular drywall in a bathroom?

Water-resistant board is better for damp areas, and neither belongs behind tile in a shower.