Orifice Flow Calculator

Flow rate through a sharp-edged orifice plate from the measured differential pressure — or the bore needed for a given flow.

Calculator

mm
mm
kPa
kg/m³
cP (mPa·s)

Leave C empty and enter the viscosity to use the ISO 5167-2 equation.

Enter C to use a fixed value instead.

Example Result

Your result will appear here

The calculated result will appear here after you press Calculate.

About the Orifice Flow Calculator

An orifice plate is a thin plate with a sharp-edged hole clamped between pipe flanges. The fluid speeds up through the hole, its pressure falls, and the pressure difference measured across the plate tells you the flow rate. Enter the pipe's inside diameter, the bore diameter, the differential pressure, the fluid density and either the discharge coefficient C or the fluid's viscosity — with the viscosity, the calculator works out C from the ISO 5167-2 Reader-Harris/Gallagher equation and the Reynolds number by iteration. The sizing mode does the reverse and finds the bore for a target flow. The guide below shows how sensitive the result is to C, works through water, oil and a 4-inch US example, and explains the limits the standard puts on β and pipe size.

How to Use the Orifice Flow Calculator

  1. 1

    Choose "Flow from ΔP" to read a meter, or "Bore sizing" to design a plate for a target flow; pick SI or Imperial.

  2. 2

    Enter the pipe inside diameter and the bore (or the target flow), the differential pressure and the fluid density.

  3. 3

    Enter the viscosity to let the calculator work out C from ISO 5167-2 (choose the tapping type), or enter a fixed C.

  4. 4

    Press Calculate. A warning appears if the plate is outside the standard's limits of use.

Orifice Flow Calculator Examples

Frequently Asked Questions

What discharge coefficient should I use?

About 0.60–0.62 for a standard sharp-edged plate at high Reynolds numbers; for better accuracy, enter the viscosity and let the calculator work out C from the ISO 5167-2 Reader-Harris/Gallagher equation.

What beta ratio should an orifice plate have?

ISO 5167-2 covers 0.1 to 0.75; mid-range values give a good balance between differential pressure and permanent pressure loss.

Why does flow change with the square root of differential pressure?

The pressure drop is converted into velocity, and kinetic energy goes with velocity squared. Halving the flow cuts the differential to a quarter.

What is the vena contracta?

The narrowest point of the jet just downstream of the plate, where velocity is highest and pressure lowest.

Can I use this for gas?

For small differentials relative to line pressure, yes, with the upstream gas density at line conditions. Otherwise multiply the flow by the ISO 5167-2 expansibility factor ε = 1 − (0.351 + 0.256β⁴ + 0.93β⁸)[1 − (p₂/p₁)^(1/κ)].

How do I size an orifice plate?

Pick a full-scale differential, enter the target flow and solve for the bore; the sizing mode iterates C for you.

By O.E. — Partner, chairman of the board and CEO of a metal products manufacturer for 21 years; the company exports to 45 countries.

Drafted with AI assistance; calculations checked against primary sources and tested with the site's own code. About FlowUtil

Last reviewed

The orifice equation

Q = C × A₀ × √(2ΔP ÷ ρ) ÷ √(1 − β⁴). The term 1 ÷ √(1 − β⁴) is the velocity-of-approach factor: the larger the bore relative to the pipe, the more the upstream velocity adds to the measurement. Mass flow is Q × ρ. Because Q varies with the square root of ΔP, a quarter of the differential pressure means half the flow — which is why orifice meters lose accuracy at the bottom of their range.

SymbolMeaning
CDischarge coefficient (about 0.60–0.62 for a standard sharp-edged plate)
A₀Bore area, π d² ÷ 4
βDiameter ratio d ÷ D
ρFluid density at the upstream tapping

Water, oil and a 4-inch line

  1. 1Water at 20 °C (998.2 kg/m³, 1.0 cP) in a 100 mm line, 50 mm bore (β = 0.5), 25 kPa, flange taps.

    C from ISO 5167-2 = 0.6060 at Re 110,361

    31.31 m³/h

    With a fixed C = 0.61 (and 1,000 kg/m³) the calculator gives 31.49 m³/h — 0.6% high: inside the uncertainty of many process meters, but not of a custody-transfer meter.

  2. 2Light oil, 870 kg/m³ and 8.7 cP, 150 mm line, 90 mm bore (β = 0.6), 40 kPa.

    C = 0.6156 at Re ≈ 34,000

    144.9 m³/h

    A fixed C = 0.60 gives 141.2 m³/h, 2.6% low. The lower the Reynolds number, the further C drifts from its high-Re value, so viscous liquids are where calculating C pays off.

  3. 3US: 4 in Schedule 40 (4.026 in inside), 2.500 in bore (β = 0.62), 100 inH₂O (3.609 psi) of differential on water.

    C = 0.6097

    234 US gpm (53.2 m³/h)

  4. 4Sizing: 30 m³/h of water in the 100 mm line at a full-scale differential of 25 kPa.

    Iterating C and the bore together

    Bore 49.0 mm (β = 0.49)

    Choose the differential range first: a higher ΔP gives a smaller bore and better turndown, but more permanent pressure loss.

The discharge coefficient (ISO 5167-2)

ISO 5167-2 gives C for standard plates through the Reader-Harris/Gallagher equation: C = 0.5961 + 0.0261β² − 0.216β⁸ + 0.000521(10⁶β/Re_D)^0.7 + (0.0188 + 0.0063A)β^3.5(10⁶/Re_D)^0.3 + (0.043 + 0.080e^(−10L₁) − 0.123e^(−7L₁))(1 − 0.11A)β⁴/(1 − β⁴) − 0.031(M₂′ − 0.8M₂′^1.1)β^1.3, with A = (19,000β/Re_D)^0.8 and M₂′ = 2L₂′/(1 − β). For flange tappings L₁ = L₂′ = 25.4 mm ÷ D; for corner tappings both are 0; for D and D/2 tappings L₁ = 1 and L₂′ = 0.47. Pipes under 71.12 mm add 0.011(0.75 − β)(2.8 − D/25.4). The equation applies within the standard's limits — bore at least 12.5 mm, pipe 50–1,000 mm, β between 0.1 and 0.75 — and the calculator warns outside them.

Gases and steam

  • ExpansibilityFor a gas the density changes across the plate. ISO 5167-2 corrects with ε = 1 − (0.351 + 0.256β⁴ + 0.93β⁸)[1 − (p₂/p₁)^(1/κ)], κ the isentropic exponent; multiply Q by ε.
  • Line densityUse the density at the upstream tapping at line conditions, not a standard density.
  • Small differentialsThe calculator treats the fluid as incompressible: for gases keep ΔP to a few percent of the absolute upstream pressure or apply ε yourself.

Sources

  1. ISO 5167-2:2003 — Measurement of fluid flow by means of pressure differential devices — Part 2: Orifice plates — standard not accessed; the equations as quoted in the two documents below
  2. Deltares — WANDA technical reference, "Orifice" component (ISO 5167-2:2003 discharge coefficient and limits of use)
  3. Equinor — NeqSim documentation, "Flow meter models" (discharge coefficient and expansibility factor)
  4. NIST Chemistry WebBook, SRD 69 — Thermophysical properties of water