Hydraulic Reservoir Size Calculator

A starting tank size from pump flow, with air space and cylinder volume added.

Calculator

L/min

For a variable pump, use the mean flow. For a closed circuit, use the charge pump.

×

3–5 industrial, 1.5–2 mobile, 5–8 HFC or HFD fluid.

%

Empty uses 10%.

L

The oil that leaves the tank with every cylinder extended.

Example Result

Your result will appear here

The calculated result will appear here after you press Calculate.

About the Hydraulic Reservoir Size Calculator

The usual starting point for a hydraulic tank is a few minutes of pump flow. Enter the flow and a multiple, then add air space and the oil your cylinders draw out. The result is a first estimate, not a design: heat, fluid type and space can all move it.

How to Use the Hydraulic Reservoir Size Calculator

  1. 1

    Enter the pump flow. Use the mean flow for a variable pump, or the charge pump flow for a closed circuit.

  2. 2

    Enter a multiple from the hint under the field.

  3. 3

    Leave air space empty for 10%, or enter your own.

  4. 4

    Add the oil your cylinders draw from the tank, then press Calculate.

Hydraulic Reservoir Size Calculator Examples

Frequently Asked Questions

How big should a hydraulic tank be?

Start with 3–5 times the pump flow per minute for industrial open circuits, then add air space and cylinder volume.

Is the three times rule still valid?

It remains a common starting point. Compact tank designs can use less, but they need careful air release.

How much air space does a tank need?

About 10% above the oil is a common allowance.

What size tank for a 20 gpm pump?

About 60–100 gal of oil for an industrial open circuit, or 30–40 gal on a mobile machine.

Does a closed-circuit system need a big tank?

No. Size it from the charge pump flow.

Do I need an oil cooler?

It depends on heat, not tank size alone. Continuous high-power systems often need one.

By O.E. — Partner, chairman of the board and CEO of a metal products manufacturer for 21 years; the company exports to 45 countries.

Drafted with AI assistance; calculations checked against primary sources and tested with the site's own code. About FlowUtil

Last reviewed

Why the rule counts minutes of flow

A tank does more than store oil. It gives returning oil time to release air, drop out dirt and water, and shed some heat. A multiple of 3 means the oil spends about three minutes in the tank on average, so the multiple is really a dwell time.

Tank oil volume = pump flow × multiple

Tank size = oil volume × (1 + air space) + cylinder volume swing

For a variable pump, use the mean flow, not the maximum. Multiples are rules of thumb from industry practice. They are not limits from a standard.

Which multiple to use

SystemMultiple of pump flow per minute
Open circuit, industrial3–5
Open circuit, fire-resistant HFC or HFD fluid5–8
Open circuit, mobile machine1.5–2
Closed circuit (hydrostatic), industrial3–5 × charge pump flow
Closed circuit, mobile1–2 × charge pump flow

Closed-circuit systems return most oil straight to the pump, so only the charge pump flow passes through the tank. Entering the main pump flow here gives a tank far too big.

Mobile machines run smaller tanks because of weight and space, and they pay for it with less margin for air and heat. Oil that has to give up air slowly, such as a thick grade in the cold, needs more dwell time, so check the grade against the viscosity reference.

An industrial power unit: 40 L/min

Pump flow is 40 L/min, the multiple is 4, and air space is 10%.

  • Oil volume: 40 × 4 = 160 L
  • With 10% air space: 176 L

How the choice of multiple changes it:

MultipleOil volume
1.560 L
3120 L
5200 L
8320 L

A US shop system: 10 gpm

Pump flow is 10 gpm, the multiple is 3, and air space is 10%.

  • Oil volume: 10 × 3 = 30 gal
  • With 10% air space: 33 gal

Add the oil that cylinders take away

When a cylinder extends, the level falls by the rod volume. Two 80/56 mm cylinders with a 500 mm stroke draw down 2.46 L, which the hydraulic oil volume calculator works out for you. On a machine with long cylinders this swing can exceed the rule's margin.

Check the low level with every cylinder extended, so the pump inlet stays covered. Check the high level with every cylinder retracted, so the tank does not overflow through the breather.

What the rule does not tell you

The multiple says nothing about heat. Heat comes from the wasted part of the pump's power, which you can find from the hydraulic pump power calculator. A system that runs at full load all day often needs a cooler whatever its tank size, while a light intermittent one may not. A cooler can also let a designer use a smaller tank.

Shape matters too. A tall thin tank has less surface for air to escape than a low wide one of the same volume, and baffles stop return oil going straight to the suction line. Pump flow itself comes from the hydraulic pump flow calculator.

Sources

  1. Brendan Casey, How to Size a Hydraulic Tank, Power & Motion, 2015.
  2. Hydraulics & Pneumatics, Fundamentals of Hydraulic Reservoirs.